◆Download Specs
Specification Sheet
■Total control of high performance heat treatment system
Temperature:
Work temperature balance (∆T) control and profiling control enabling substantial work temperature control.
Ambient gas:
Program analog retransmission output in parallel with temperature control enabling detection of ambient gas and control of density by mass flow controller etc.
Reliable uniform heating:
Continuously monitors electric furnace heater resistance by the Heater Monitoring Unit; model ZE7201, and its expedient alarm function works for preventive detection of electric heater wear-out then uniform heating for the work is guaranteed.
Keep Time:
Keep time triggered and initiated by temperature balance for surface and core of the work for ensuring even sintering treatment.
■Variety of input/output functions
Input:
control input (1 ~ 3ch), precise analog input (for profiling, ∆T control: 3 inputs max.)
Output:
control output (1 ~ 3ch), analog retransmission (output for configuring mass flow controller, etc: 3 outputs max.)
DI/DO:
16 points max.
each Communication interface:
RS-232C, RS-422A, GP-IB
Extended function:
ARCNET®
■Multiple control of up to 3 channels per single unit
Control channel:
Programmable control of up to 3 zones per single unit.
Up to 18 channels controllable by ARCNET® (Control by 6 units max.)
■Variety of program loop
4 program linked control
(Ex.: Temperature, gas and pressure)
Program biased control
(Ex.: 3 zones temperature control)
3 program independent control
(Ex.: Independent furnace control)
■High performance
High accuracy: ± 0.05%+ 1 digit
High resolution: 0.01°C (Pt 100, JPt 100)
■TFT large full-color liquid crystal display (103 × 75mm)
Enable operators to see quickly control results on real-time trend screen.
Easy programming of data input with graphic pattern on the same display.
■IC Memory Card
Program pattern, PID constants, Parameters, SET UP data can be stored.
■Safety standards UL, CSA